Reports until 20:10, Tuesday 12 March 2024
H1 ISC
gabriele.vajente@LIGO.ORG - posted 20:10, Tuesday 12 March 2024 (76312)
Attempt at A2L

[Gabriele, Elenna]

Since we saw high coherence betwen DHARD_Y and DARM, we tried to improve the A2L. In summary, the current value of 1.65 is the best for angular coupling at ~30 Hz, so we didn't change it.

To do the measurement, we injected two lines, one at 15.1 Hz and one at 30.3 Hz, and used a python script to demodulate the lines in DARM. The lowest coupling at 15.1 Hz is obtained for a larger value around -2.4, but this makes the coupling at 30.3 Hz larger. The initial value is the best for minmize the coupling at 30 Hz, where DHARD is limitign DARM.

Images attached to this report