Displaying report 1-1 of 1.
Reports until 09:28, Wednesday 13 March 2024
H1 ISC
camilla.compton@LIGO.ORG - posted 09:28, Wednesday 13 March 2024 - last comment - 11:57, Wednesday 13 March 2024(76323)
Intensity Noise Injections Ran at 16:10UTC

Followed Naoki's 70642 instructions. Pushed to aligoNB git. There was a small EQ passing through just before I started this. Had ~3dB of constant SQZ.

Last ran and analyzes aligoNB injections with hot and cold OM2 in December 74943 / 74788. We haven't measured coupling of frequency and intensity noise since August 2023: 72140.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 11:07, Wednesday 13 March 2024 (76332)

Followed Naoki's instructions for running aligoNB 74788. Using  data  from 1387120622 2023-12-20 15:16 UTC (cold OM2, observing,  IFO locked 11.5 hours, 160Mpc) with today's intensity noise injections.

See attached plot, above 300Hz laser intensity noise is a factor of 2 to 5 above August measurement (Laser NB plot from Aug 2023 -alog 72770) but still low. We don't see any contributions in 30-300Hz range.

Non-image files attached to this comment
craig.cahillane@LIGO.ORG - 11:32, Wednesday 13 March 2024 (76336)
Wow, not very coherent for a signal appearing that strongly in DARM. 
camilla.compton@LIGO.ORG - 11:57, Wednesday 13 March 2024 (76339)

Adding the coherence plots for LF and MF, low freq coherence is only 0.3, maybe th reason we see no intensity noise contrusion 30-300Hz.

We could think about repeating with higher gains, Craig also suggests doing the frequency noise injections (70642) as MF and HF noise can be seen in DARM but coherence is not 1, maybe the coupling mechanism is frequency noise.

Images attached to this comment