H1 SUS PR3 Phase 3b Acceptance Measurement -- Undamped Top2Top TFs
Checking it off Arnaud's list so I can get on to installing Level 2.1 filters, I've taken final Phase 3b, undamped, M1 to M1 transfer functions of H1 SUS PR3, an HLTS. Now that Hugo's not shaking HPI, all degrees of freedom look gorgeous. We should consider this measurement of H1 SUS PR3 as accepted. As per usual, the individual results and results compared against other similar suspensions are posted below. Everything mentioned below has been committed to the repo as of the post of this entry.

Note, the remaining Phase 3b acceptance measurements for H1 SUS PR3 are:
- Damped transfer functions of M1 to M1 (I didn't take these, because I'm going to be installing new damping filters shortly)
- M2 to M2 and M2 to M3 (I'll be taking these now)
- Spectra of all stages. (These are quick, I'll just take these when new damping filters are installed.)

Details
-------
The data was taken with the following DTT templates:
${SusSVN}/sus/trunk/HLTS/H1/PR3/SAGM1/Data/
2013-09-05_1743_H1SUSPR3_WhiteNoise_L_0p01to50Hz.xml
2013-09-05_1743_H1SUSPR3_WhiteNoise_P_0p01to50Hz.xml
2013-09-05_1743_H1SUSPR3_WhiteNoise_R_0p01to50Hz.xml
2013-09-05_1743_H1SUSPR3_WhiteNoise_T_0p01to50Hz.xml
2013-09-05_1743_H1SUSPR3_WhiteNoise_V_0p01to50Hz.xml
2013-09-05_1743_H1SUSPR3_WhiteNoise_Y_0p01to50Hz.xml

The data from which was exported as:
${SusSVN}/sus/trunk/HLTS/H1/PR3/SAGM1/Data/
2013-09-05_1743_H1SUSPR3_WhiteNoise_L_0p01to50Hz_tf.txt
2013-09-05_1743_H1SUSPR3_WhiteNoise_P_0p01to50Hz_tf.txt
2013-09-05_1743_H1SUSPR3_WhiteNoise_R_0p01to50Hz_tf.txt
2013-09-05_1743_H1SUSPR3_WhiteNoise_T_0p01to50Hz_tf.txt
2013-09-05_1743_H1SUSPR3_WhiteNoise_V_0p01to50Hz_tf.txt
2013-09-05_1743_H1SUSPR3_WhiteNoise_Y_0p01to50Hz_tf.txt

The data was individually processed by:
${SusSVN}/sus/trunk/HLTS/Common/MatlabTools/plotHLTS_dtttfs.m

which produced the following saved data (and the individual plots):
${SusSVN}/sus/trunk/HLTS/H1/PR3/SAGM1/Results/2013-09-05_1743_H1SUSPR3_M1.mat

This saved data was then compared against other measurements using:
${SusSVN}/sus/trunk/HLTS/Common/MatlabTools/plotallhlts_tfs.m

The resulting plot is saved in:
${SusSVN}/sus/trunk/HLTS/Common/Data/
Non-image files attached to this report