Reports until 13:41, Wednesday 13 March 2024
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 13:41, Wednesday 13 March 2024 (76347)
Status Report: New-and-improved WD System on TMTSs works great; Typical motion is 0.02 um_RMS, and Max motion is 0.1 um_RMS (Threshold still at 25 um_RMS)
J. Kissel

Checking the last day's worth of BLRMS values of the Transmission Monitor and Telescope Suspensions (TMTS) TMSX and TMSY M1 or top-mass OSEMs to compare against the arbitrarily chosen threshold of 25 [um_RMS] in the 0.1 - 10 Hz band -- typical values are ~0.02 [um_RMS] and maximum excursions after lock losses are 0.3 [um_RMS].

We could probably safely decrease the WD threshold to something like 1 [um_RMS].

See attached ~24 hour trend of the TMSX and TMSY BLRMS channels vs. the ISC_LOCK guardian state.