IAS: J. Oberling
SUS: B. Weaver
Finished the ITMx cartridge alignment today, position/angle errors are as follows:
-
Longitudinal Error: -2.3 mm (South)
-
Lateral Error: +0.05 mm (West)
-
Vertical Error: +0.08 mm (high)
-
Pitch Error: 30 µrad up
-
Actual Pitch: 589 µrad down
-
Target: 619.0 µrad down
-
Tolerance: ±50.0 µrad
-
Yaw Error: 30 µrad CCW
-
Target: 0.0 µrad
-
Tolerance: ±50.0 µrad
We also roughed in the CPx pitch by eye. We will set up tomorrow to measure the ITMx/CPx gap and finish the pitch/yaw alignment of the CPx.