Checking on HWS, no new Point Absorbers

Looking at a  power up (comparing when we get to 60W input as reference time to 40s and 120s later), we can see no evidence of point absorbers on ITMY after 120s and 40s. On ITMX after 120s and  40s can see our known point absorbers 66197.

Attached the spherical power trends of, ITMX changes 118μDiopters, ITMY changes 103μDiopter (double pass). It is expected the ITMX curvature  will change more due to the point absorbers.

TCS SIM current status (sitemap > TCS > SIMULATION):