Reports until 16:14, Thursday 14 March 2024
H1 CAL (ISC)
jeffrey.kissel@LIGO.ORG - posted 16:14, Thursday 14 March 2024 (76392)
H1 CAL CS ETMX Actuator Model of Digital Filters Updated to Allow for New DARM Distribution Filters
J. Kissel, L. Dartez

In prep for calibrating the detector under the "new DARM" control scheme (see e.g. some of the conversation in LHO aLOGs 76315  75308), I've copied over the new filters that are needed from the H1SUSETMX.txt filter file over to the H1CALCS.txt filter file. The new filters are only in the replica of L2 LOCK, L1 LOCK, L3 DRIVEALIGN, and L2 DRIVEALIGN, and I only needed to copy over two filters.

I've committed the H1CALCS.txt to the userapps repo.
    /opt/rtcds/userapps/release/cal/h1/filterfiles/
        H1CALCS.txt

Attached is a screenshot highlighting the new filters copied over.
Images attached to this report