Reports until 17:55, Thursday 14 March 2024
H1 CAL
louis.dartez@LIGO.ORG - posted 17:55, Thursday 14 March 2024 - last comment - 12:47, Friday 15 March 2024(76396)
DARM PSD with updated CAL-CS filters activated
The CAL-CS filters installed by Jeff (LHO:76392) do a better job of correcting CAL-DELTAL_EXTERNAL. See darm_fom.png. Here's a screenshot of the filter banks: new_darm_calcs_filters.png.

Also, Evan's 5Hz high pass filter (LHO:76365) pretty much killed the strong kick we've been seeing each time we switch into this new DARM state from ETMY. 
Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 12:47, Friday 15 March 2024 (76428)

The rms drive to the ESD is now about 5000 DAC counts on each quadrant, dominated by motion around 3 Hz.

Images attached to this comment