O4a |
Optical gain H_c * k_c = 3.363e6 cts/m |
Relative 1.012 |
|
Before OMC realignment |
Optical gain H_c * k_C = 3.322e6 ct/m |
Relative 1.000 |
|
After OMC realignment Kappa_C = 1.02 (from trend) |
Optical gain H_c * k_C = 3.388e6 ct/m |
Relative 1.020 |
|
After OMC realignment Kappa_c = 0.993 (2024-03-15 15:45 LT) still trending up |
Optical gain H_c * k_C = 3.370e6 ct/m |
Relative 1.015 |
With this new value of the optical gain, when Kappa_c = 1, the optical gain would be 2.1% higher than before the OMC realignment.