Reports until 16:02, Friday 15 March 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:02, Friday 15 March 2024 (76439)
OPS Day Shift Summary

TITLE: 03/15 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is in NLN and COMISSIONING

Control Room Operation Log 03/15

 ———————————————————— Shift begin to Nominal Low Noise

15:42 UTC - NLN

16:30 UTC - Erik rebooting Nuc29 due to it flipping on and off - successful

 ———————————————————— Nominal Low Noise to Lockloss/Lock Attempt 1

17:03 UTC - Lockloss ISI EX Stage 1, 2, SUS EX, SUS TMSX WD tripped due to commissioning (known reason)

17:34 - Resetting WDs reset - Counts got to 136 for LL AC on L2.

17:36 -  Started locking - stopping at Damp Bounce for some commissioning tests (Jennie and Craig)

17:55 - Guardian restarted with NEW_DARM being the new (nominal) DARM.

18:02 - BS touched by Georgia in order to improve BS - but went into MICH_FRINGES before much movement

18:05 - Lockloss at CHECK_MICH_FRINGES - relocking now.

18:07 - Pointed out by TJ, and trended to confirm - the ALS X TRX is much lower than the last few lock attempts. It was hovering around 1.2 yesterday and is maxing at 0.7 today despite a high comm beat note (~6). This might warrant an initial alignment if the current lock attempt fails. 

18:25 - BS moved by Georgia to acquire PRMI - success 

18:26 - DRMI Locked

18:32 - Lockloss DRMI

 ———————————————————— Lock Attempt 1 to Init Align

18:32 - Initial Alignment Started 

18:40 - Initial Alignment Strangeness - while ALS locked for both arms, the WFs took a while to offload, keeping us in this state for longer than expected - alogged by Camilla (alog 76423)

18:47 - ALSX Transmission values are back to what they were yesterday - around 1.2. Expecting this to fix DRMI locking issues.

19:02 - Initial Alignment Complete - requested CHECK_VIOLINS_BEFORE_POWERUP for Jennie/Craig to run their tests.

 ———————————————————— Init Align to Lock Attempt 2

19:21 - Reached CHECK_VIOLINS_BEFORE_POWERUP for Jennie to take her measurements.

19:26 - Tests done, NLN requested

19:29 - HAM7 WD Tripped - potentially due to SQZ work - requested pre-squeeze state - ADS_TO_CAMERAS. Camilla letting Naoki and Nutsinee know - checking WD now.

19:34 - WD reset successfully.

19:40/1 - Requested and reached TRANSITION_FROM_ETMX for commissioning work.

19:54 - Lockloss - DRMI unlocked (reason not immediately apparent)

 ———————————————————— Lockloss to Lock Attempt 3

20:30 - Lockloss - DRMI unlocked at LOWNOISE_ASC (Alenna caused via changes made in that state)

20:47 - Gerardo informed the control room that the computing room across from the control room had a loud fan and that the back wall was vibrating - informed facilities and Tyler is investigating. Nothing was wrong according to Tyler and Eric.

21:18 - Locked and in NOMINAL_LOW_NOISE

 ———————————————————— Nominal Low Noise to Shift End

22:38 - Craig Running CARM Injection Tests

22:48 - Craig’s Tests done - preparing for future injections

LOG:

Start Time System Name Location Lazer_Haz Task Time End
17:25 VAC Jordan, Gerardo LVEA N Cart Transport 17:39
18:28 FAC Tyler MY N Roof inspection 19:28
19:11 SQZ Daniel, Nutsinee, Naoki LVEA N Switch 19:41
19:41 CDS Erik, Marc EX N Environmental Protection Procurement (jacket) 20:05
20:01 SQZ Nutsinee LVEA N Quick Measurement 20:06
22:12 PSL Craig, Matthew, Graeme LVEA N CARM Injection Preparation 23:12
Images attached to this report