[Elenna, Louis] We reduced the amplitudes of the L2 and L3 SUS calibration lines. Both lines were way too loud after moving to the new DARM loop offloading configuration. The settings we ended up on are below: Line | Freq | Gain | DELTA_L/SUS_EXC uncertainty L2 | 16.4 Hz | 1.5 | 0.0058 L3 | 17.6 Hz | 0.061 | .0046 For each step I changed all of the following channels: H1:SUS-ETMX_L2_CAL_LINE_CLKGAIN, H1:SUS-ETMX_L2_CAL_LINE_SINGAIN, H1:SUS-ETMX_L2_CAL_LINE_COSGAIN, H1:CAL-CS_TDEP_SUS_LINE2_COMPARISON_OSC_CLKGAIN, H1:CAL-CS_TDEP_SUS_LINE2_COMPARISON_OSC_SINGAIN, H1:CAL-CS_TDEP_SUS_LINE2_COMPARISON_OSC_COSGAIN I'm attaching the CAL-CS SUS Line screens for both lines. Red boxes highlight the gains that we adjusted.