Reports until 18:44, Saturday 16 March 2024
H1 ISC
gabriele.vajente@LIGO.ORG - posted 18:44, Saturday 16 March 2024 - last comment - 19:29, Saturday 16 March 2024(76460)
MICH FF retuned

I measured again MICH and SRCL FF. I could fit a MICH filter that improves the subtraction. SRCL is still work in progres.

The new MICH FF filter is loaded into FM1, it's better so I'll put in in guardian.

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 19:29, Saturday 16 March 2024 (76463)

There is now almost no coherence with MICH, and with SRCL only at the ~100 Hz jitter peaks. So I think the current LSC FF are good.