Reports until 16:01, Sunday 17 March 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:01, Sunday 17 March 2024 (76467)
OPS Day Shift Summary

TITLE: 03/17 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is at LOCKING and at CARM_5_PICOMETERS (309)

(15:00 UTC 0- 21:45 UTC) ISI IY Interface Chassis is dead and requires replacement:

ISI IY WD tripped around 3AM - I go to untrip right now, it trips again, triggering our last lockloss.  (09:48 UTC)

Looking at the values, they are all below threshold so I untrip and then <1 minute later, it trips again. I try this one more time while trending the relevant channel, T240 ISI Stage 1and the counts climb uo irrattically until it trips again (<1 min later). After ensuring, Screenshots of this behavior below.

I get in contact with Jim, and he informs me that the corner 1 sensors are all dead, indicating an interface chassis issue. With instructions, I go to the CER to power cycle but it stays dead. Photos of the dead chassis below.

After getting a hold of Fernando, him and Richard were able to get a hold of Fil, who said he would come to site to do the replacement/fix (according to Richard).

Jim noticed that the Chassis came back at 10:53 but that we should stay down until Fil investigates.

At around 21:00 UTC, Fil arrived and we replaced the Chassis with a functional one. Fil stayed until ALSY locked, confirming that the issue was fixed.

21:25 UTC - Began Locking

22:23 UTC - Started Initial Alignment due to CHECK MICH FRINGES ran and failed for the 3rd time and manual touching of BS and PRM was going nowhere.

22:49 UTC - Initial Alignment Complete, locking now

22:56 UTC - DRMI Locked - requested NLN

Other:

EX Pressure EX_X5_PT526 MOD1 PRESS TORR is showing a yellow alert on the vacuum alarm handler.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
21:00 OPS Ibrahim CER N Power cycling interface chassis 22:00
20:51 PCAL Rick Optics Lab N Grabbing something to ship to LLO 21:21
22:27 EE Fil, Ibrahim CER N Interface chassis replacement 22:27