Reports until 12:59, Friday 22 March 2024
H1 PSL
ryan.short@LIGO.ORG - posted 12:59, Friday 22 March 2024 (76632)
PSL Status Report - Weekly

FAMIS 26236

Laser Status:
    NPRO output power is 1.819W (nominal ~2W)
    AMP1 output power is 67.15W (nominal ~70W)
    AMP2 output power is 138.3W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN

PMC:
    It has been locked 21 days, 21 hr 9 minutes
    Reflected power = 16.84W
    Transmitted power = 109.0W
    PowerSum = 125.9W

FSS:
    It has been locked for 0 days 11 hr and 41 min
    TPD[V] = 0.8342V

ISS:
    The diffracted power is around 2.3%
    Last saturation event was 0 days 11 hours and 41 minutes ago


Possible Issues: None reported