Reports until 13:47, Saturday 23 March 2024
H1 General (ISC, Lockloss)
ryan.short@LIGO.ORG - posted 13:47, Saturday 23 March 2024 (76655)
Lockloss @ 20:39 UTC from M7.0 EQ - ETMY A2L Gain Step Script Partially Complete

Lockloss @ 20:39 UTC from M7.0 quake out of Papua New Guinea, lock stretch was 6:17. Earthquake mode activated 4 minutes prior.

I was running the A2L stepper script for ETMY when the EQ hit; output of the progress made below:

Start time:

PDT: 2024-03-23 10:34:21.512854 PDT
UTC: 2024-03-23 17:34:21.512854 UTC
GPS: 1395250479.512854

ryan.short@cdsws29[/ligo/gitcommon/labutils/beam_spot_raster]: python a2l_gain_stepper.py ETMY --start "now"
Waiting for start time...
starting p2l: 4.6
starting y2l: 3.2
Adjusting P2L gains @ 1395250501.0 to to 4.3999999999999995
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.3999999999999995
Now waiting for 900 seconds
Adjusting P2L gains @ 1395251402.0 to to 4.199999999999999
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.199999999999999
Now waiting for 900 seconds
Adjusting P2L gains @ 1395252302.0 to to 4.3999999999999995
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.3999999999999995
Now waiting for 900 seconds
Adjusting P2L gains @ 1395253202.0 to to 4.6
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.6
Now waiting for 900 seconds
Adjusting P2L gains @ 1395254102.0 to to 4.8
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.8
Now waiting for 900 seconds
Adjusting P2L gains @ 1395255002.0 to to 5.0
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 5.0
Now waiting for 900 seconds
Adjusting P2L gains @ 1395255902.0 to to 4.8
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.8
Now waiting for 900 seconds
Adjusting P2L gains @ 1395256802.0 to to 4.6
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.6
Now waiting for 900 seconds
Adjusting Y2L gains @ 1395257702.0 to to 3.0
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 3.0
Now waiting for 900 seconds
Adjusting Y2L gains @ 1395258602.0 to to 2.8000000000000003
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 2.8000000000000003
Now waiting for 900 seconds
Adjusting Y2L gains @ 1395259502.0 to to 3.0
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 3.0
Now waiting for 900 seconds
Adjusting Y2L gains @ 1395260402.0 to to 3.2
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 3.2
Now waiting for 900 seconds
Adjusting Y2L gains @ 1395261302.0 to to 3.4000000000000004
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 3.4000000000000004