J. Kissel ECR E1700387 IIET 9392 WP 11743 Tomorrow, we continue on the adventure towards upgrading the suspension watchdog systems that Oli, Dave and I have been chugging along on for the previous two weeks (see, eg, LHO aLOGs 76305, 76269 and 76545). This week, we're tackling a big chunk -- all of the HAM triple suspensions, both large and smal, i.e. the 7 HSTS and 2 HLTS. Note :: these are the final suspensions that are hooked up to their respective ISIs, so this should be the last major upgrade. As such I've: In the SUS model library parts, - Converted the BLRMS trigger generating systems to include a trust-worthy RMS calculation, coupled with a down-stream low-pass filter, - Removed all evidence of the USER DACKILL watchdog aggregator system - While I was there, I removed remaining evidence of the long-defunct / depricated "online detector characterization" ODC system, long since replaced by guardian state information On the top level SUS models, - Removed all evidence of the USER DACKILL watchdog aggregator system - Removed the IPC sender of the USER DACKILL to the respective ISI - Verified that the removal of library block output ports didn't botch any of the top level connections, reconnecting and re-organizing as needed On the top level of the ISI models, - Replaced the IPC receiver of the USER DACKILL watchdog from all respective SUS which impacts all of the following models: Top Level ISI Top Level Optic Governing Library Part h1isiham2.mdl h1susmc1.mdl HSTS_MASTER.mdl h1susmc3.mdl HSTS_MASTER.mdl h1suspr3.mdl HLTS_MASTER.mdl h1susprm.mdl RC_MASTER.mdl h1isiham3.mdl h1susmc2.mdl MC_MASTER.mdl h1suspr2.mdl RC_MASTER.mdl h1isiham4.mdl h1sussr2.mdl RC_MASTER.mdl h1isiham5.mdl h1sussr3.mdl HLTS_MASTER.mdl h1sussrm.mdl RC_MASTER.mdl (no change to isiham7) h1susfc1.mdl HSTS_MASTER.mdl (no change to isiham8) h1susfc2.mdl HSTS_MASTER.mdl In addition, some of the lower level SUS library parts were also impacted, SIXOSEM_T_STAGE_MASTER.mdl FOUROSEM_STAGE_MASTER.mdl FOUROSEM_STAGE_MASTER_OPLEV.mdl All of the above model changes have been committed to the userapps SVN repo in revs 27310, 27311, 27312, and 27313.