Displaying report 1-1 of 1.
Reports until 08:12, Tuesday 26 March 2024
H1 SUS (ISC, SEI, SUS)
jeffrey.kissel@LIGO.ORG - posted 08:12, Tuesday 26 March 2024 (76703)
HAM SEI and HAM Triple SUS Prepped for Model Restarts
J. Kissel, T. Shaffer
ECR E1700387
IIET 9392
WP 11743

In prep for today's watchdog upgrades (LHO:76696), TJ and I have 
   - Ensured all HAM triple SUS have their alignment offsets accepted / stored in their safe.snap (they're typically unmonitored, so this takes special action)
   - Brought the IMC guardian to OFFLINE, and brought the guardian to "AUTO" such that it's no longer managed by ISC_LOCK
   - Brought the MC2, PRM, PR2, SR2, SRM gguardians to "AUTO" such that they're no longer managed
   - Brought MC1, MC2, MC3, PRM, PR2, PR3, SRM, SR2, SR3, FC1, and FC2 to SAFE
   - Brought SEI MANAGER guardians for HAM2, HAM3, HAM4, HAM5, HAM7, and HAM8 to ISI_DAMPED_HEPI_OFFLINE

We're ready for restarts!
Displaying report 1-1 of 1.