J. Kissel ECR E1700387 IIET 9392 WP 11743 After - yesterday's front-end code model prep (LHO:76696), - TJ and I's prep for front-end code installation (LHO:76703), and - Dave's code installation (LHO:76706) I spent the rest of the morning filling in the upgraded watchdog infrastructure for the HAM Triples, i.e. MC1, MC2, MC3, PRM, PR2, PR3, SRM, SR2, SR3, FC1, and FC1. All HAM Triples' WD RMS MAX thresholds have been set to 150 [um_RMS] As with the QUADs and Beam Splitter -- please feel free to edit as we gain more experience with normal things that happen during IFO operation. The following has been committed / was affected by today's upgrade. MEDM SCREEN MODS /opt/rtcds/userapps/release/sus/common/medm/hxts/ SUS_CUST_HXTS_M1_WD_OSEMAC_RMSLP.adl SUS_CUST_HXTS_M2_WD_OSEMAC_RMSLP.adl SUS_CUST_HXTS_M3_WD_OSEMAC_RMSLP.adl SUS_CUST_HXTS_WD.adl SUS_CUST_HLTS_OVERVIEW.adl SUS_CUST_HSTS_OVERVIEW.adl FOTON FILE MODS /opt/rtcds/userapps/release/sus/h1/filterfiles/ (all of the above mentioned foton filter files) SDF FILE MODS /opt/rtcds/userapps/release/sus/h1/burtfiles/ (all relevant _safe.snap and _OBSERVE.snap files) GUARDIAN MODS /opt/rtcds/userapps/release/sus/common/scripts/ sustools.py Attached are my detailed notes.