Reports until 16:03, Friday 06 September 2013
H1 ISC
jeffrey.kissel@LIGO.ORG - posted 16:03, Friday 06 September 2013 (7672)
H1 IMC up after power outtage
J. Kissel, M. Barton, H. Paris [D. Feldbaum via phone]

After getting the PSL back up, it took very little time to get the mode cleaner re-locked. 
Hugo - restored the HAM2 and HAM3 isolation systems to proper alignment
Mark - restored the mode cleaner suspensions to yesterday's alignment
JSK / Mark - burt restored h1ascimc model to regain the input periscope's PZT alignment

Mark had left Stefan's MClockwatch running on opsws3, as I had done Wednesday which happily picked it up the mode cleaner flashes and brought us to a pretty nice* lock. 

Win! Boy are we close to having a fully automated input optics chain...

*The alignment looks a little funky, but Mark's seeing plenty enough SNR to get what he needs done up at 500+ [Hz], so we're not gunna bother tweaking it.