PSL Status Report - Weekly

FAMIS 26237

Laser Status:
    NPRO output power is 1.815W (nominal ~2W)
    AMP1 output power is 67.19W (nominal ~70W)
    AMP2 output power is 138.2W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN

PMC:
    It has been locked 30 days, 18 hr 28 minutes
    Reflected power = 17.13W
    Transmitted power = 108.9W
    PowerSum = 126.0W

FSS:
    It has been locked for 0 days 19 hr and 0 min
    TPD[V] = 0.8157V

ISS:
    The diffracted power is around 2.4%
    Last saturation event was 0 days 19 hours and 0 minutes ago


Possible Issues: None reported