Reports until 09:33, Monday 01 April 2024
H1 ISC
camilla.compton@LIGO.ORG - posted 09:33, Monday 01 April 2024 - last comment - 13:00, Thursday 04 April 2024(76838)
Measured MICH LSC feedforward
Followed /lsc/h1/scripts/feedforward/README.txt 
Last done March 16th: 76460, suggestion to refit in 76766.
Measured for MICH but we lost lock during SRCL injections. Plan to refit for MICH, current FF attached, it's worse than March 16th fit in 10-35Hz region.
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:26, Monday 01 April 2024 (76859)

I saved an improved fit into FM6 as "04-01-24" but have not yet loaded coefficients. Plan to test it tomorrow.

Images attached to this comment
camilla.compton@LIGO.ORG - 13:00, Thursday 04 April 2024 (76956)

Tested this new FM6 once IFO had been locked 12 hours. New FF looked better, plot attached. Leaving it on from 19:45UTC.

Images attached to this comment