Last Friday and today, I worked on installing remaining TMS cable and documenting each cable for TMS. The table below documents cables we installed, positions on Cable Brackets, and what components they are hooked up to. For in-air cabling, we only had the SUS cables run to the Test Stand; this is why I don't have names for these ISC TMS cables.
In-Air Cable |
Chamber feed-thru |
In-vac cable | Cable Bracket | In-Vac Cable |
Cable Bracket on TMS |
In-Vac Component |
---|---|---|---|---|---|---|
H1:SUS_BSC9_TMONX-1("SUS1") | ..........||......... | D1000225 s/n S1106816 | CB3, 1st floor | D1000234 s/n V2-96-903 | --- | OSEMS: Face1, Face2, Face3, Left |
H1:SUS_BSC9_TMONX-4("SUS2") | ..........||......... | D1000225 s/n S1106771 | CB3, 2nd floor | D1000234 s/n V2-88-934 | --- | OSEMS: Right, Side, ---, --- |
: Not sure of name, cable not run : | ..........||......... | D1000924 s/n S1104104 | CB6, 1st floor | D1000568 s/n S1104110 | CB-primary, 1st floor | Green QPD (D1000231 s/nS1202413) |
: Not sure of name, cable not run : | ..........||......... | D1000924 s/n S1203963 | CB6, 2nd floor | D1000568 s/n S1202739 | CB-primary, 2nd floor | Red QPD (D1000231 s/nS1202411) |
: Not sure of name, cable not run : | ..........||......... | D1000223 s/n S1202653 | CB5, 1st floor | D1000921 s/n S1104112* | CB-entry, 2nd floor | Picomotors (D1000238 s/n S1105218) |
: Not sure of name, cable not run : | ..........||......... | D1000223 s/n S1202656 | CB5, 2nd floor | D1000921 s/n S1104113 | CB-entry, 1st floor | Beam Diverter (D1000237 s/n S1202724) |
in-vac cable | cable bracket | in-vac cable | in-vac component |
H1:SUS_BSC9_TMONX-1("SUS1") |
in-vac cable | cable bracket | in-vac cable | in-vac component |
H1:SUS_BSC9_TMONX-1("SUS1") |
These cables are run mainly according to D1300007, although we did make some changes to improve workability (see photo). One unfortunate thing here is, in D1300007, there is mention of a cable to be used, and there is a note that for this cable, having "metal ears" is optional. So we went without them here, but with the ears NOT on the cable, it makes it impossible to disconnect a cable from a cable bracket (see photo) without having to also remove the cable bracket from the table (this is because when the cables are connected via a set screw, the set screw access hole is blocked when connected cables are attached to the Cable Bracket). LAME.
I also set up equipment for testing cables...mainly this was bringing lots of stuff which are needed for the Picomotor cables.
* For D1000921 S1104112 above, this cable was originally noted as S11041111 due to bag, but looks like the bag was mis-labeled. S1104112 is what is really installed.
not sure why of all the empty lines after the table above. :-/