Displaying report 1-1 of 1.
Reports until 12:51, Tuesday 02 April 2024
H1 PEM (PEM)
marc.pirello@LIGO.ORG - posted 12:51, Tuesday 02 April 2024 (76882)
EX Accelerometer Testing

Per WP11795 I looked at the EX Accelerometer Power Conditioner based on what Robert said about one of the channels not functioning.  Visually, there is no power on channel 8, the power good light is off.  We moved the signal to channel 9 and will go back to fix channel 8 when time permits.  This channel was working when the chassis was installed.

Images attached to this report
Displaying report 1-1 of 1.