Summary (highlights) of findings during the DQ Shift -Engineering run with ongoing commissioning -Numerous lock-losses due to earthquakes/seismic activity -BNS range averages between 145 and 150 Mpc. Sometimes there are fluctuations to 130 Mpc. -Glitchgrams show a reoccuring glitch around 40 Hz that occurs a few times a day. -The h(t) spectrogram showed sporatatic increases of amplitude relative to the median in low-frequency range. Anomalies can be associated with drops in BNS range. -Fscans are unavailable at this time. -A few pyCBC triggers with new SNR > 10 (short) occured 2 out of 7 days. -PEM, ASC and LSC type channels showed often as round winners in Hveto associated with low-frequency noise around 40 Hz and 50 Hz respectively. -New channels of interest include IMC and HPI. Channel activity can be linked to sustained winds. Also could be round winners because of shorter observation runs. DQ Shift Report: https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20240318