Reports until 23:36, Tuesday 02 April 2024
H1 SUS
oli.patane@LIGO.ORG - posted 23:36, Tuesday 02 April 2024 - last comment - 05:39, Thursday 04 April 2024(76900)
Weekly In-Lock SUS Charge Measurements

Ran the data for the In Lock SUS Charge Measurements that ran this morning. Like Camilla said (76895), the excitations only worked for the ETMs, so although I am attaching all four plots, note that the last plot point for the ITMs is March 13th (ETMX, ETMY, ITMX, ITMY).

Images attached to this report
Comments related to this report
artem.basalaev@LIGO.ORG - 05:39, Thursday 04 April 2024 (76946)
Adding these measurement results also calculated with new scripts. As far as I can see, similar trends show up with the caveat that signs of variables are sometimes different.

By the way this makes me wonder a bit. We'd assumed that ETMX got charged up during the break, but the absolute value of beta and beta2 (which determine linear force component strength - see eq.3 in T1700446) for ETMX in last two measurements go down in both old and new calculation. Isn't it the opposite of what we'd expect?
Images attached to this comment