WP11743 SUS DACKILL removal and WD consolidation
Jeff, Oli, Dave
New models were install for h1susim, h1sushtts, h1sussqzin, h1sussqzout, h1susifoout. No SEI model changes were needed, IOP models were not restarted so no SWWD bypass was necessary. DAQ restart was required.
Beckhoff OPLEV upgrade
Fernando, Daniel, Dave:
New OPLEV code was installed on the Beckhoff slow controls, resulting in additional 20 slow channels to H1EPICS_ECATAUX[CS,EX,EY]. EDC+DAQ restart was required.
PSL Neolase Beckhoff code change
Patrick, Ryan S, Dave:
The PSL Diode room Beckhoff code was modified, resulting in one additional channel (H1:PSL-LASER_PDWD) in H1EPICS_PSLNEOLASE.ini. EDC+DAQ restart was required.
DAQ Restarts
Jeff, Dave:
The DAQ was restarted twice. The first around 09:30 immediately after the SUS model changes, and then a second time with an EDC restart around 11:30 to support the Beckhoff changes.
GDS Broadcast List Change:
The h1susifoout change resulted in the removal of 6 fast channels (256Hz) from the frame, of which 2 were being sent DMT via the GDS broadcaster. ECR2400116 was created and approved to cover this removal.
--: fast channel H1:SUS-OMC_M1_ASC_L_IN1_DQ removed from the DAQ
-!: fast channel H1:SUS-OMC_M1_ASC_P_IN1_DQ removed from the DAQ ***GDS-CHAN***
--: fast channel H1:SUS-OMC_M1_ASC_R_IN1_DQ removed from the DAQ
--: fast channel H1:SUS-OMC_M1_ASC_T_IN1_DQ removed from the DAQ
--: fast channel H1:SUS-OMC_M1_ASC_V_IN1_DQ removed from the DAQ
-!: fast channel H1:SUS-OMC_M1_ASC_Y_IN1_DQ removed from the DAQ ***GDS-CHAN***
To expediate the broadcast list change, I hand editied the gds_broadcast.ini file on h1daqgds[0,1]. This needs to be made permanent in puppet.
Three fast channels were added to the frame:
++: fast channel H1:SUS-OMC_M1_LOCK_L_IN1_DQ added to the DAQ
++: fast channel H1:SUS-OMC_M1_LOCK_P_IN1_DQ added to the DAQ
++: fast channel H1:SUS-OMC_M1_LOCK_Y_IN1_DQ added to the DAQ
Tue02Apr2024
LOC TIME HOSTNAME MODEL/REBOOT
09:20:16 h1sush2b h1susim <<< SUS MODEL RESTARTS
09:20:36 h1sush2b h1sushtts
09:21:39 h1sush56 h1susifoout
09:22:00 h1sush56 h1sussqzout
09:22:49 h1sush7 h1sussqzin
09:31:24 h1daqdc0 [DAQ] <<< FIRST DAQ RESTART
09:31:36 h1daqfw0 [DAQ]
09:31:36 h1daqtw0 [DAQ]
09:31:37 h1daqnds0 [DAQ]
09:31:45 h1daqgds0 [DAQ] (NEW BRD LIST)
09:34:35 h1daqdc1 [DAQ]
09:34:48 h1daqfw1 [DAQ]
09:34:48 h1daqtw1 [DAQ]
09:34:51 h1daqnds1 [DAQ]
09:34:59 h1daqgds1 [DAQ] (NEW BRD LIST)
09:35:58 h1daqfw0 [DAQ] <<< FW0 Spontaneous restart
11:15:36 h1sush7 h1sussqzin <<< 2ND SQZIN RESTART, PARTS FOUND TO BE MISSING
11:30:51 h1daqdc0 [DAQ] <<< 2ND DAQ RESTART FOR BECKHOFF AND SUSSQZIN
11:31:01 h1daqfw0 [DAQ]
11:31:01 h1daqtw0 [DAQ]
11:31:02 h1daqnds0 [DAQ]
11:31:09 h1daqgds0 [DAQ]
11:31:41 h1susauxb123 h1edc[DAQ] <<< EDC RESTART
11:32:19 h1daqgds0 [DAQ] <<< 2ND GDS0 RESTART NEEDED
11:35:01 h1daqdc1 [DAQ]
11:35:14 h1daqfw1 [DAQ]
11:35:15 h1daqtw1 [DAQ]
11:35:18 h1daqnds1 [DAQ]
11:35:26 h1daqgds1 [DAQ]
11:36:01 h1daqgds1 [DAQ] <<< 2ND GDS1 RESTART NEEDED
11:51:00 h1daqnds1 [DAQ]