Coherences from last night

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1396341217_GDS_CALIB_CLEAN/
DHARD_Y is pretty bad, much worse than usual. Probably need a retuning of A2L

Comments related to this report
camilla.compton@LIGO.ORG - 09:30, Friday 05 April 2024 (76980)

Jennie, Sheila, Camilla

We expect DHARD yaw to be worse.  In the seconds half of last night's lock the CAM_YAW1 offset was changed by ~7 counts, see 76961.  It is expected that A2L would need to be retuned, we are still working on adding these  76961 changes to the guardian.