TITLE: 04/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1:
INCOMING OPERATOR: Oli
SHIFT SUMMARY:
- 15:00 - H1 working through initial alignment
- SRY having trouble catching; adjusted SRM alignment by hand, still had to lower SCRL trig threshold to catch
- 15:52 - Initial alignment complete, starting lock acquisition
- PRMI ASC ran twice (very little improvement)
- DRMI finally caught after some alignment by hand, but buildups still look bad
- 16:42 - Lockloss from DRMI, starting manual initial alignment
- Fixed dark offsets duing input alignment (alog76982)
- 17:29 - Initial alignment complete, starting lock acquisition
- 18:19 - Reached NLN, straightforward acquisition
- 19:04 - Started observing (since no commissioning activities happening)
- 19:48 - Dropped observing for HAM1 ASC FF off
- 20:31 - Lockloss from camera servo commissioning tests
- 20:53 - Erik restarting seismon
- 21:32 - Reached NLN, unassisted acquisition
- 22:11 - To NLN_CAL_MEAS for A2L gain tests and broadband PCal measurement
- 23:07 - Started observing
LOG:
| Start Time |
System |
Name |
Location |
Lazer_Haz |
Task |
Time End |
| 16:15 |
FAC |
Kim |
H2 |
- |
Technical cleaning |
16:23 |
| 16:41 |
VAC |
Gerardo |
LVEA |
- |
Retrieving aux cart |
16:48 |
| 21:37 |
VAC |
Gerardo, Jordan |
MX |
- |
Retrieving cable trays |
22:26 |