Displaying report 1-1 of 1.
Reports until 15:08, Friday 05 April 2024
H1 PSL
ryan.short@LIGO.ORG - posted 15:08, Friday 05 April 2024 (76988)
PSL Status Report - Weekly

FAMIS 26238

I added the PDWD to this script after the first time I ran this.

Laser Status:
    NPRO output power is 1.811W (nominal ~2W)
    AMP1 output power is 66.96W (nominal ~70W)
    AMP2 output power is 137.3W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 3 days, 3 hr 59 minutes
    Reflected power = 17.61W
    Transmitted power = 108.3W
    PowerSum = 125.9W

FSS:
    It has been locked for 0 days 4 hr and 45 min
    TPD[V] = 0.8019V

ISS:
    The diffracted power is around 2.3%
    Last saturation event was 0 days 1 hours and 29 minutes ago

Possible Issues: None reported