FAMIS 26488, last checked in alog75989
There are 12 T240 proof masses out of range ( > 0.3 [V] )!
ITMX T240 1 DOF X/U = -1.14 [V]
ITMX T240 1 DOF Y/V = 0.364 [V]
ITMX T240 1 DOF Z/W = 0.471 [V]
ITMX T240 3 DOF X/U = -1.177 [V]
ITMY T240 3 DOF X/U = -0.535 [V]
ITMY T240 3 DOF Z/W = -1.549 [V]
BS T240 1 DOF Y/V = -0.368 [V]
BS T240 3 DOF Y/V = -0.326 [V]
BS T240 3 DOF Z/W = -0.464 [V]
HAM8 1 DOF X/U = -0.366 [V]
HAM8 1 DOF Y/V = -0.365 [V]
HAM8 1 DOF Z/W = -0.647 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.065 [V]
ETMX T240 1 DOF Y/V = -0.021 [V]
ETMX T240 1 DOF Z/W = -0.058 [V]
ETMX T240 2 DOF X/U = -0.259 [V]
ETMX T240 2 DOF Y/V = -0.209 [V]
ETMX T240 2 DOF Z/W = -0.212 [V]
ETMX T240 3 DOF X/U = -0.01 [V]
ETMX T240 3 DOF Y/V = -0.14 [V]
ETMX T240 3 DOF Z/W = -0.003 [V]
ETMY T240 1 DOF X/U = 0.122 [V]
ETMY T240 1 DOF Y/V = 0.136 [V]
ETMY T240 1 DOF Z/W = 0.202 [V]
ETMY T240 2 DOF X/U = -0.059 [V]
ETMY T240 2 DOF Y/V = 0.187 [V]
ETMY T240 2 DOF Z/W = 0.114 [V]
ETMY T240 3 DOF X/U = 0.218 [V]
ETMY T240 3 DOF Y/V = 0.15 [V]
ETMY T240 3 DOF Z/W = 0.142 [V]
ITMX T240 2 DOF X/U = 0.17 [V]
ITMX T240 2 DOF Y/V = 0.274 [V]
ITMX T240 2 DOF Z/W = 0.277 [V]
ITMX T240 3 DOF Y/V = 0.176 [V]
ITMX T240 3 DOF Z/W = 0.151 [V]
ITMY T240 1 DOF X/U = 0.111 [V]
ITMY T240 1 DOF Y/V = 0.095 [V]
ITMY T240 1 DOF Z/W = 0.014 [V]
ITMY T240 2 DOF X/U = 0.065 [V]
ITMY T240 2 DOF Y/V = 0.24 [V]
ITMY T240 2 DOF Z/W = 0.114 [V]
ITMY T240 3 DOF Y/V = 0.084 [V]
BS T240 1 DOF X/U = -0.185 [V]
BS T240 1 DOF Z/W = 0.117 [V]
BS T240 2 DOF X/U = -0.077 [V]
BS T240 2 DOF Y/V = 0.038 [V]
BS T240 2 DOF Z/W = -0.138 [V]
BS T240 3 DOF X/U = -0.169 [V]
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.089 [V]
STS EY DOF Z/W = 2.831 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.506 [V]
STS A DOF Y/V = -0.75 [V]
STS A DOF Z/W = -0.641 [V]
STS B DOF X/U = 0.431 [V]
STS B DOF Y/V = 0.933 [V]
STS B DOF Z/W = -0.456 [V]
STS C DOF X/U = -0.681 [V]
STS C DOF Y/V = 0.854 [V]
STS C DOF Z/W = 0.421 [V]
STS EX DOF X/U = -0.072 [V]
STS EX DOF Y/V = 0.052 [V]
STS EX DOF Z/W = 0.046 [V]
STS EY DOF Y/V = 0.101 [V]
STS FC DOF X/U = 0.252 [V]
STS FC DOF Y/V = -1.001 [V]
STS FC DOF Z/W = 0.692 [V]