Reports until 06:12, Tuesday 09 April 2024
H1 CDS
david.barker@LIGO.ORG - posted 06:12, Tuesday 09 April 2024 - last comment - 10:48, Wednesday 10 April 2024(77040)
h1omc0 channel hop caused dolphin glitch of SUS and LSC

Oli, Erik, Dave:

Around 04:30 this morning a ADC channel hop on h1iopomc0 caused all of the omc0 models to stop running, and also caused a corner station Dolphin glitch which DACKILLED h1susb123, h1sush34, h1sush56 and h1lsc0.

Comments related to this report
david.barker@LIGO.ORG - 06:14, Tuesday 09 April 2024 (77041)

h1omc0 dmesg:

[Tue Apr  9 04:34:05 2024] rts_cpu_isolator: LIGO code is done, calling regular shutdown code
[Tue Apr  9 04:34:05 2024] h1iopomc0: ERROR - A channel hop error has been detected, waiting for an exit signal.
[Tue Apr  9 04:34:05 2024] h1omcpi: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
[Tue Apr  9 04:34:05 2024] h1omc: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
 

david.barker@LIGO.ORG - 06:22, Tuesday 09 April 2024 (77042)

Initially I thought this was an IO Chassis issue, so we power cycled h1omc0 rather than a restart all of its models (my confusion was because this front end only has one Adnaco, and is running the low-noise ADC). This brought h1omc0 back up and running.

We restarted the models on h1lsc0, which cleared the DACKILL.

Oli put the SUS and SEI for BSC1,2,3 and HAM3,4,5,6 into safe, I SWWD bypassed the SEI IOPs  and we restarted the models on h1susb123, h1sush34, h1sush56. All came back with no problems.

I cleared the SWWDs, did a DIAG_RESET and cleared the DAQ CRCs.

Handing over to Oli for IFO recovery.

david.barker@LIGO.ORG - 06:35, Tuesday 09 April 2024 (77043)

CDS Overview after DIAG_RESET run on all front ends:

Images attached to this comment
david.barker@LIGO.ORG - 06:39, Tuesday 09 April 2024 (77045)

Time of OMC crash:

04:32:45 PDT

11:32:45 UTC

1396697583 GPS

david.barker@LIGO.ORG - 10:48, Wednesday 10 April 2024 (77089)