daniel.sigg@LIGO.ORG - posted 09:00, Tuesday 09 April 2024 (77049)
CLF VCO Sensitivity

Measured the sensitivity of the new CLF VCO:

Offset at Tune Input Tune readback Frequency (MHz) Difference (kHz)
-1V 3.332V 202.690924 436.1
0V 4.067V 203.127060 0
+1V 4.800V 203.542136 415.1

which results in ~425kHz/V.