Displaying report 1-1 of 1.
Reports until 11:02, Thursday 11 April 2024
H1 ISC (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 11:02, Thursday 11 April 2024 (77113)
Initial alignment SRY triggering moved from POP_A to AS_C

Following up from my alog77064 saying that this needed to change, today I moved SRY triggering from POP_A_DC to AS_C_NSUM with new trigger threshold of upper=0.005 and lower=0.004. This worked well and gave us a quick, well aligned DRMI during main locking. The Acquire_SRY state used to lower the trigger thresholds after a few minutes for times that we had less power on POP_A, I've removed the lowering but added a notification to check the alignment or triggering.

I've updated ALIGN_IFO to reflect this and committed to the SVN. I anticipate we might need to fine tune these thresholds over the coming weeks.

Images attached to this report
Displaying report 1-1 of 1.