WP11812
Jamie, Jonathan, Erik, Dave:
The two CAL HASH channels (H1:CAL-CALIB_REPORT_HASH_INT and H1:CAL-CALIB_REPORT_ID_INT) were moved from the h1calcs model, where they were being acquired as single-precision floats, to a new custom EPICS IOC called cal_hash_ioc, where they are acquired as signed 32bit integers.
The h1calcs.mdl model was modified to remove the EPICS-INPUT parts for these channels. The model was then restarted.
The IOC, which was being tested with H3 channels, was modifed and rstarted to serve the H1 channels as integers.
The EDC was modified to add H1EPICS_CALHASH.ini to its master list. This added 5 channels the the DAQ, the two hash channels and three IOC status channels.
The EDC was restarted, followed in short order by a DAQ restart.
Tue16Apr2024
LOC TIME HOSTNAME MODEL/REBOOT
10:04:52 h1oaf0 h1calcs <<< Model change to remove channels
10:07:51 h1susauxb123 h1edc[DAQ] <<< EDC has the new channels
10:08:43 h1daqdc0 [DAQ] <<< 0-leg restart, no issues
10:08:55 h1daqfw0 [DAQ]
10:08:55 h1daqnds0 [DAQ]
10:08:55 h1daqtw0 [DAQ]
10:09:03 h1daqgds0 [DAQ]
10:11:55 h1daqdc1 [DAQ] <<< 1-leg restart, no issues
10:12:06 h1daqfw1 [DAQ]
10:12:07 h1daqtw1 [DAQ]
10:12:08 h1daqnds1 [DAQ]
10:12:16 h1daqgds1 [DAQ]
SDF for CAL-CALIB_REPORT_HASH_INT accepted