For FAMIS 26240:
Laser Status:
NPRO output power is 1.813W (nominal ~2W)
AMP1 output power is 66.77W (nominal ~70W)
AMP2 output power is 139.1W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 16 days, 21 hr 17 minutes
Reflected power = 17.33W
Transmitted power = 108.7W
PowerSum = 126.0W
FSS:
It has been locked for 0 days 9 hr and 51 min
TPD[V] = 0.8222V
ISS:
The diffracted power is around 2.5%
Last saturation event was 0 days 10 hours and 2 minutes ago
Possible Issues:
Check diode chiller