WP11816 Add CAL GDS_HASH channel to DAQ and GDS Broadcaster
Jamie, Erik, Jonathan, Dave
A new channel, H1:CAL-CALIB_REPORT_GDS_HASH_INT, as added to the cal_hash_ioc EPICS IOC. It was added to the DAQ via EDC, and also added to the DAQ GDS-Broadcaster for transission to GDS.
The new channel is being monitored by the CDS SDF.
WP11821 New h1asc model
Jeff, Dave:
We installed Jeff's new h1asc model. DAQ restart was required for the addtion of 4 slow chanels.
WP11822 FMCS STAT upgrade
Erik, Dave:
Erik installed new FMCS STAT code. This also added new channels to the DAQ, requiring a DAQ+EDC restart.
DAQ Restart
Jonathan, Dave:
Jonathan made the recent GDS Broadcast channel additions permanent in puppet and regenerated the GDS channel lists.
We restarted the DAQ and EDC for the above changes. No issues with this restart.
One issue I found with the h1asc change is that the gain for the ASC_DHARD EC20Hz filter changed at the 15th decimal place. I followed my standard procedure of ensuring H1ASC.txt was committed to subversion, did the 'rtcds install h1asc' which modifies the filter file header block, then corrected this by running 'foton -c H1ASC.txt'. After this the only svn diff in the file is the gain change
-ASC_DHARD_Y 7 12 5 10240 0 EC20Hz 4.246651939748587456513462e-01 -1.9976820160389552 0.9977451970061935 -1.9973471518970052 0.9974295203382628
+ASC_DHARD_Y 7 12 5 10240 0 EC20Hz 4.246651939748589676959512e-01 -1.9976820160389552 0.9977451970061935 -1.9973471518970052 0.9974295203382628
Tue23Apr2024
LOC TIME HOSTNAME MODEL/REBOOT
08:00:38 h1asc0 h1asc <<< New asc model
08:05:00 h1daqdc0 [DAQ] << 0-leg restart
08:05:13 h1daqfw0 [DAQ]
08:05:13 h1daqtw0 [DAQ]
08:05:14 h1daqnds0 [DAQ]
08:05:22 h1daqgds0 [DAQ] <<< new BROADCAST ini
08:05:27 h1susauxb123 h1edc[DAQ] <<< EDC for cal_hash and fmcs_stat changes
08:11:21 h1daqdc1 [DAQ] <<< 1-leg restart
08:11:31 h1daqfw1 [DAQ]
08:11:32 h1daqtw1 [DAQ]
08:11:33 h1daqnds1 [DAQ]
08:11:59 h1daqgds1 [DAQ] <<< new BROADCAST ini