CDS Maintenance Summary: Tuesday 23rd April 2024

WP11816 Add CAL GDS_HASH channel to DAQ and GDS Broadcaster

Jamie, Erik, Jonathan, Dave

A new channel, H1:CAL-CALIB_REPORT_GDS_HASH_INT, as added to the cal_hash_ioc EPICS IOC. It was added to the DAQ via EDC, and also added to the DAQ GDS-Broadcaster for transission to GDS.

The new channel is being monitored by the CDS SDF.

WP11821 New h1asc model

Jeff, Dave:

We installed Jeff's new h1asc model. DAQ restart was required for the addtion of 4 slow chanels.

WP11822 FMCS STAT upgrade

Erik, Dave:

Erik installed new FMCS STAT code. This also added new channels to the DAQ, requiring a DAQ+EDC restart.

DAQ Restart

Jonathan, Dave:

Jonathan made the recent GDS Broadcast channel additions permanent in puppet and regenerated the GDS channel lists.

We restarted the DAQ and EDC for the above changes. No issues with this restart.

Comments related to this report
david.barker@LIGO.ORG - 09:04, Tuesday 23 April 2024 (77342)

One issue I found with the h1asc change is that the gain for the ASC_DHARD EC20Hz filter changed at the 15th decimal place. I followed my standard procedure of ensuring H1ASC.txt was committed to subversion, did the 'rtcds install h1asc' which modifies the filter file header block, then corrected this by running 'foton -c H1ASC.txt'. After this the only svn diff in the file is the gain change

-ASC_DHARD_Y 7 12 5  10240      0 EC20Hz     4.246651939748587456513462e-01  -1.9976820160389552   0.9977451970061935  -1.9973471518970052   0.9974295203382628
+ASC_DHARD_Y 7 12 5  10240      0 EC20Hz     4.246651939748589676959512e-01  -1.9976820160389552   0.9977451970061935  -1.9973471518970052   0.9974295203382628
 

david.barker@LIGO.ORG - 09:15, Tuesday 23 April 2024 (77344)

Tue23Apr2024
LOC TIME HOSTNAME     MODEL/REBOOT
08:00:38 h1asc0       h1asc       <<< New asc model


08:05:00 h1daqdc0     [DAQ] << 0-leg restart
08:05:13 h1daqfw0     [DAQ]
08:05:13 h1daqtw0     [DAQ]
08:05:14 h1daqnds0    [DAQ]
08:05:22 h1daqgds0    [DAQ] <<< new BROADCAST ini


08:05:27 h1susauxb123 h1edc[DAQ] <<< EDC for cal_hash and fmcs_stat changes


08:11:21 h1daqdc1     [DAQ] <<< 1-leg restart
08:11:31 h1daqfw1     [DAQ]
08:11:32 h1daqtw1     [DAQ]
08:11:33 h1daqnds1    [DAQ]
08:11:59 h1daqgds1    [DAQ] <<< new BROADCAST ini