Reports until 14:48, Tuesday 23 April 2024
H1 ISC (Lockloss)
camilla.compton@LIGO.ORG - posted 14:48, Tuesday 23 April 2024 - last comment - 09:19, Monday 06 May 2024(77359)
Locklosses at state TRANSISITON _FROM_ETMX

Jennie, TJ, Camilla

The Operator team has been seeing more locklosses at state 557 TRANSISITON _FROM_ETMX, more so when the wind is high. Times: 1397719797; 1397722896; 1397725803; 1397273349, 1397915077

Last night we had a lockloss from 558 LOWNOISE_ESD_ETMX with a 9Hz ITMX L3 oscillation, see attached. Compare to a successful transition (still has glitch).

Note that there is a glitch ~30s before state 558 in both cases.  H1:SUS-ETMX_L3_DRIVEALIGN_L2L and _L3_LOCK_L filter changes happens here. Are ramp times finished before these changes?

The timing of the glitch is 2 m 55 seconds after we get to state 557, this is the same time as in the 4 of the last 6  state 557 locklosses.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:42, Tuesday 23 April 2024 (77366)

Louis, Camilla. Investigations ongoing but the timing of this glitch is suspiciously when the H1:SUS-ETMX_L1_LOCK_L gain and filters are changed, tramp is 1secinds but FM2 and FM6 foton filters have a 3 seconds ramp. There is an INPUT to this filter bank before the gain and filters are turned on. Plot attached.

Images attached to this comment
camilla.compton@LIGO.ORG - 09:19, Monday 06 May 2024 (77642)

In 77640 we show that the DARM1 filter change is the cause of the glitches/locklosses.