PSL Status Report - Weekly

FAMIS 26241

Laser Status:
    NPRO output power is 1.82W (nominal ~2W)
    AMP1 output power is 67.0W (nominal ~70W)
    AMP2 output power is 138.8W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 23 days, 21 hr 48 minutes
    Reflected power = 17.88W
    Transmitted power = 108.6W
    PowerSum = 126.5W

FSS:
    It has been locked for 1 days 3 hr and 40 min
    TPD[V] = 0.8223V

ISS:
    The diffracted power is around 2.2%
    Last saturation event was 1 days 3 hours and 51 minutes ago
 

Possible Issues: None reported