Retuned SRCL FF

[Jennie, Sheila, Gabriele]

We retuned the SRCL FF, by doing the usual injections. While fitting, we just tried to change the gain of the filter that was running a bit, and that was enough to get an improved subtraction. The new filter module (FM2) is active and in guardian.