Displaying report 1-1 of 1.
Reports until 21:46, Monday 29 April 2024
H1 General (SQZ)
anthony.sanchez@LIGO.ORG - posted 21:46, Monday 29 April 2024 - last comment - 23:30, Monday 29 April 2024(77498)
Monday Ops Eve Mid Shift update

TITLE: 04/30 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Commissioning
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 9mph Gusts, 7mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.17 μm/s
QUICK SUMMARY:
H1 is still locked but we have fallen into commisioning due to the SQZ ISS Pump.
Looking at Alog 70050 I have requested LOCKED_CLF_DUAL_NO_ISS
I changed the opo_grTrans_setpoint_uW from 80 to 50...

Reloaded and then noticed that the comments said that 50 was too low. I was still reading comments when Naoki got onto TeamSpeak and saved the day.
He said that 70 may be appropriate but 50 is too low due to the SQZ system being tuned for 80. please see
alog 72044 .

H1 Is back in Now back in Observing.




 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 23:30, Monday 29 April 2024 (77500)

the following SDF was accepted after Naoki was done.

Images attached to this comment