Displaying report 1-1 of 1.
Reports until 13:40, Wednesday 01 May 2024
H1 General (Lockloss)
thomas.shaffer@LIGO.ORG - posted 13:40, Wednesday 01 May 2024 - last comment - 14:17, Wednesday 01 May 2024(77549)
Lock loss 2010UTC

1398629440

This lock loss had that the weird ETMX wiggle just before the lock loss that we've seen in past lock losses.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 14:17, Wednesday 01 May 2024 (77550)

Back to Observing. Full auto relock but there was an SDF diff for the ITMY CP that was changed during commissioning in the Observe.snap, and came back after this last lock loss. I saved the new values in the safe.snap as well.