Ops EVE Shift End

TITLE: 05/02 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: During relocking we were able to catch DRMI without needing to go through PRMI, but had locklosses from ENGAGE_DRMI_ASC and TURN_ON_BS_STAGE2 before I started an initial alignment. During initial alignment we couldn't get past WFS_CENTERING_SRY, so I just took us out of IA and started relocking. LVEA is still in LASER HAZARD.

LOG:

22:49 Detector Locked for 2 hours
00:10 Dropped Observing to run SQZ and regular calibrations
00:19 Went to NLN_CAL_MEAS for calibration measurements
00:30 Earthquake mode activated
00:50 Back to NOMINAL_LOW_NOISE and Observing
01:00 Seismic to CALM

04:59 Lockloss
05:10 Lockloss from ENGAGE_DRMI_ASC
05:18 Lockloss from TURN_ON_BS_STAGE2 - started an initial alignment
05:37 - 05:45 Stuck at SRC alignment
    - Constant SRM, IFO_OUT, SQUEEZE_OUT saturations
    - We weren't able to get past WFS_CENTERING_SRY, so I took us to DOWN
    - Backed out of initial alignment and started relocking
06:27 NOMINAL_LOW_NOISE
06:30 Observing

Start Time System Name Location Lazer_Haz Task Time End
21:25 SQZ Terry, Camilla Opt Lab Local SHG work, new CO2 test 23:51
22:09 PCAL Rick, Fransisco PCAL lab local PCAL tasks 00:09
23:16 VAC Janos, Jordan MY n Turn off CP3 pump 23:31
Comments related to this report
ryan.crouch@LIGO.ORG - 09:11, Thursday 02 May 2024 (77568)

ASC_AS_C wasn't really seeing much light during the WFS_CENTERING_SRY align attempts?

Images attached to this comment