Minhyo, Sheila
Changed the gain values of the RANGE BLRMS's filters (RLP_1 ~ 7) at 17:48:44 (UTC).
I referenced the accumulated BNS range in Apr.-11 and Apr.-17, to reverse calculated the additional factors for the filter gains (1/BNS = scope * factor).
The New gain values are defined as (Prev. gain) * (Avg. Factor).
Attached three screenshots are; 1) Accumulated BNS range plot, 2) Factor calculation, 3) H1OAF.diff after made all changes.