Displaying report 1-1 of 1.
Reports until 08:26, Friday 03 May 2024
H1 SEI
anthony.sanchez@LIGO.ORG - posted 08:26, Friday 03 May 2024 (77596)
SEI ground seismometer mass position check - Monthly

Famis 26489

Output of Check_T240_Centering.py :

Averaging Mass Centering channels for 10 [sec] ...
2024-05-03 08:16:49.261630


There are 13 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.343 [V]
ITMX T240 1 DOF X/U = -1.206 [V]
ITMX T240 1 DOF Y/V = 0.358 [V]
ITMX T240 1 DOF Z/W = 0.461 [V]
ITMX T240 3 DOF X/U = -1.244 [V]
ITMY T240 3 DOF X/U = -0.572 [V]
ITMY T240 3 DOF Z/W = -1.611 [V]
BS T240 1 DOF Y/V = -0.379 [V]
BS T240 3 DOF Y/V = -0.334 [V]
BS T240 3 DOF Z/W = -0.476 [V]
HAM8 1 DOF X/U = -0.35 [V]
HAM8 1 DOF Y/V = -0.396 [V]
HAM8 1 DOF Z/W = -0.671 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.077 [V]
ETMX T240 1 DOF Y/V = -0.04 [V]
ETMX T240 1 DOF Z/W = -0.073 [V]
ETMX T240 2 DOF Y/V = -0.269 [V]
ETMX T240 2 DOF Z/W = -0.275 [V]
ETMX T240 3 DOF X/U = -0.023 [V]
ETMX T240 3 DOF Y/V = -0.155 [V]
ETMX T240 3 DOF Z/W = -0.024 [V]
ETMY T240 1 DOF X/U = 0.09 [V]
ETMY T240 1 DOF Y/V = 0.12 [V]
ETMY T240 1 DOF Z/W = 0.18 [V]
ETMY T240 2 DOF X/U = -0.071 [V]
ETMY T240 2 DOF Y/V = 0.172 [V]
ETMY T240 2 DOF Z/W = 0.094 [V]
ETMY T240 3 DOF X/U = 0.193 [V]
ETMY T240 3 DOF Y/V = 0.115 [V]
ETMY T240 3 DOF Z/W = 0.125 [V]
ITMX T240 2 DOF X/U = 0.164 [V]
ITMX T240 2 DOF Y/V = 0.264 [V]
ITMX T240 2 DOF Z/W = 0.259 [V]
ITMX T240 3 DOF Y/V = 0.157 [V]
ITMX T240 3 DOF Z/W = 0.146 [V]
ITMY T240 1 DOF X/U = 0.099 [V]
ITMY T240 1 DOF Y/V = 0.088 [V]
ITMY T240 1 DOF Z/W = 0.002 [V]
ITMY T240 2 DOF X/U = 0.061 [V]
ITMY T240 2 DOF Y/V = 0.233 [V]
ITMY T240 2 DOF Z/W = 0.103 [V]
ITMY T240 3 DOF Y/V = 0.076 [V]
BS T240 1 DOF X/U = -0.193 [V]
BS T240 1 DOF Z/W = 0.104 [V]
BS T240 2 DOF X/U = -0.087 [V]
BS T240 2 DOF Y/V = 0.025 [V]
BS T240 2 DOF Z/W = -0.149 [V]
BS T240 3 DOF X/U = -0.184 [V]


Assessment complete.
-------------------------------------------------
 Output of check_sts_centering.py

Averaging Mass Centering channels for 10 [sec] ...


2024-05-03 08:22:21.261255
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.063 [V]
STS EY DOF Z/W = 2.831 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.495 [V]
STS A DOF Y/V = -0.773 [V]
STS A DOF Z/W = -0.624 [V]
STS B DOF X/U = 0.396 [V]
STS B DOF Y/V = 0.958 [V]
STS B DOF Z/W = -0.457 [V]
STS C DOF X/U = -0.711 [V]
STS C DOF Y/V = 0.876 [V]
STS C DOF Z/W = 0.425 [V]
STS EX DOF X/U = -0.04 [V]
STS EX DOF Y/V = 0.053 [V]
STS EX DOF Z/W = 0.085 [V]
STS EY DOF Y/V = 0.04 [V]
STS FC DOF X/U = 0.245 [V]
STS FC DOF Y/V = -1.019 [V]
STS FC DOF Z/W = 0.679 [V]


Assessment complete.

 

Displaying report 1-1 of 1.