ITMX transfer functions ran overnight are showing a better agreement with the model after the recent modifications (see alog 7755). Results are described below
(1) In black ITMX last TF, after aligning two top mass osems and adjusting lower mass face EQ stops , compared with the measurement took 2 days ago, after having retracted top EQ stop touching the top of the test mass (in orange), compared with the model
(2) In red, ITMX last TF compared with wire rehang model
Data Scripts and PDF files have been commited to the svn