Displaying report 1-1 of 1.
Reports until 14:58, Saturday 04 May 2024
H1 CAL
anthony.sanchez@LIGO.ORG - posted 14:58, Saturday 04 May 2024 (77612)
Calibration Sweep

Calibration Sweep notes:
 I waited until the Drive Actuations for the Sus EX mode9 Violin were below 800 before running the Calibration sweep to hopefully minimize lockloss potential.
Ran the Following at 20:40 UTC ~GPS: 1398890536:
pydarm measure --run-headless bb 

notification: end of test
diag> save /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240504T204058Z.xml
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240504T204058Z.xml saved
diag> quit
EXIT KERNEL

2024-05-04 13:46:08,970 bb measurement complete.
2024-05-04 13:46:08,970 bb output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240504T204058Z.xml
2024-05-04 13:46:08,970 all measurements complete.

Then the following was ran :
gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/src/simulines/simulines/newDARM_20231221/settings_h1_newDARM_scaled_by_drivealign_20231221_factor_p1.ini;gpstime

Start:
GPS: 1398890967.961527
Stop:
GPS: 1398892259.616687

2024-05-04 21:10:41,542 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240504T204910Z.hdf5
2024-05-04 21:10:41,550 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240504T204910Z.hdf5
2024-05-04 21:10:41,555 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240504T204910Z.hdf5
2024-05-04 21:10:41,560 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240504T204910Z.hdf5
2024-05-04 21:10:41,565 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240504T204910Z.hdf5

Images attached to this report
Displaying report 1-1 of 1.