Reports until 13:18, Monday 06 May 2024
H1 CAL (CAL, ISC)
joseph.betzwieser@LIGO.ORG - posted 13:18, Monday 06 May 2024 - last comment - 13:31, Monday 06 May 2024(77654)
DHARD ASC signals seem to be sensing DARM (as witnessed by PCAL line)
[Joe B, Louis D, Vlad B]
In an attempt to understand some of the strange low frequency sensing measurements made at LHO, we've been looking at alternative paths between sensing (meters of motion at the mirror) and actuation back on the mirror that might not go through the typical DARM filter bank.

While looking, we found that there is clear line coupling (i.e. lines above a certain height in DARM) to the DHARD_Y (and DHARD_P) ASC input. Interestingly, the PCALY transmitter channel (so the power on the PCAL laser before it bounces off the optic) is clearly seen by the DHARD_Y loop, shown in attached image.  The PCAL is a separate actuator from what the ASC loops use to actuate, and thus knows nothing about angle and length coupling.  One can also see all the other calibration lines also showing up very clearly in DHARD_Y as well.  If there is imperfect diagonalization of the ASC outputs such that they couple back into length, this effectively becomes a parasitic path parallel to DARM.
Images attached to this report
Comments related to this report
vladimir.bossilkov@LIGO.ORG - 13:22, Monday 06 May 2024 (77655)

A boader look at ASC coherence to DARM. attached, sees some board lower coherences, but it is hard to say if they are just co-witnessing something or direct-cross sensing.

However for DHARD_Y and DHARD_P its pretty obvious even just looking at the power spectra that DHARD is seeing DARM signals like the bounce/roll modes and all of the Calibration lines.
The fact that all of the calibration lines are the same amplitudes in DHARD indicates this is a sensing issue.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 13:31, Monday 06 May 2024 (77657)

In 2019 we did some investigations of this, with a similar conclusion (that the low frequency sensing function is impacted by DHARD being sensitive to DARM) 50511