Displaying report 1-1 of 1.
Reports until 17:59, Monday 06 May 2024
H1 SUS (ISC)
jenne.driggers@LIGO.ORG - posted 17:59, Monday 06 May 2024 (77669)
First look at damping triples' bounce and roll modes

Sheila and Jeff have been looking at the idea of trying to damp some of the triples' bounce and roll modes (mostly the bounce modes), since we seem to be seeing some of them in DARM.  The alog thread with notes and candidate IDs for some of the modes starts with alog 77182.  While we may not end up wanting to actually damp these modes during Observing (especially if it broadens them), we would at least like to know which modes are associated with a suspension, since other modes could be associated with environmental factors (like HVAC fans).

After chatting with Sheila this morning, I interleaved some attempts at actuating on some of those modes with other work that was going on during this morning's commissioning time. The initial idea was to use a length signal (eg DARM) that we already have access to (via the LSC output matrix) and try to actuate on a triple suspension that is not used for length locking. I ran into some hiccups, but then at least tried something.  I think we'll need some model changes in order to try much more.

The challenges:

The successes:

Some thoughts:

Displaying report 1-1 of 1.