Reports until 01:10, Tuesday 07 May 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 01:10, Tuesday 07 May 2024 - last comment - 09:19, Tuesday 07 May 2024(77674)
OPS Eve Shift Summary

TITLE: 05/07 Eve Shift: 23:00-08:00 UTC (16:00-01:00 PST), all times posted in UTC
STATE of H1: Observing at 149Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 02:14 UTC (5 hr 58 min lock)

When the wind died down, I was able to successfully relock with an initial alignment. SDF Diff Screenshots attached.

Other:

Guardian SEI_ENV node in error keeps happening (3 times now after hitting load). It seems that the issue happens when CONF runs through an 1800s (30 min) checking loop - Jim on leave so didn't contact. There was an E_X saturation a few mins before it happened for the first time though (tenuous link and I do not think it is connected). Screenshot 3 shows the error log.

Had some trouble restarting Nuc5 (was going into it to get channel names). The startup code looks like its running but is taking a while to display anything (still the case after more than 5 mins as shift is ending).
 

LOG:

Start Time System Name Location Lazer_Haz Task Time End
01:34 VAC Janos CP3, MX N Pump transport 02:05
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:19, Tuesday 07 May 2024 (77678)

Correct value for ETMY_L3_LOCK_BIAS is -4.9 77656, ISC_LOCK has now been loaded so we'll need to accept sdf diff on relock today.